IGT S+ Error Codes

ERROR CODES FOR IGT S+ SLOT MACHINES

Error Code

Error Description

Most Common Repair

12

Low Battery Voltage has dropped below 2.9 VReplace ASAP due to possible RAM (memory) corruption.

Turn power off - Turn power on

Open / close door to clear

Replace Battery on MPU

21

Coin In Error

Verify that comparitor is seated in all four acceptor clips

Verify that acceptor does not have coin(s) jammed

Verify that the coin optics is not blocked (below comparitor)

Ensure toggle power switch in activated (if installed)

3100

Coin Out Tilt (Hopper)

Check for and clear any jammed coins in the coin out channel.

Verify that coins are not jammed behind hopper knife

Check the coin out optic sensor for blockage or dirty surface

Replace hopper coin out optic

3200

Extra Coin Out (Hopper)

Verify that the hopper motor brake functions

Check the coin wiper/ knife for jams - Adjust if necessary

3300

Hopper Empty

This is the most common error that new slot machine owners will have because the cash out button was pushed and the number of coins in the hopper is less than the total credits to be paid out. Open the main door and check the hopper for coin level (your hopper will not dispense all of the coins), refill and close the main door. You may have to do this several times for all of the credits to be paid out.

41

Reel #1 Tilt

Designated reel is misaligned or malfunctioning.
Verify reel is not unplugged.
Switch connectors from one reel to another, determine if error follows change of connectors. Try replacing reel assembly or optics if error stays with bad reel.
Clear Ram

42

Reel #2 Tilt

43

Reel #3 Tilt

44

Reel #4 Tilt

45

Reel #5 Tilt

49

Reel Mechanism Disconnected

Verify reels are not unplugged

61

CMOS RAM Error

Bad (or cleared) CMOS RAM data
Press test button 3 seconds
Error code 61-1 should now be displayed
Follow 61-1

61-1

Game Data Reset

Close door - turn and release reset key once

62

Bad Game EPROM

Check circuit board - replace Game EPROM

62-1

Data EPROM Error

Check circuit board - replace Reel EPROM

65-0

Bad EPROM Device

Press self test switch for 3 seconds
If error will not clear replace EPROM

65-1

Bad EPROM Data

Processor could not read or write to the named chip
Press test button for 3 seconds
Error code clears from display - Close door

65-2

Game Type Mismatch

65-3

EPROM / Game Data Changed

Close door - turn reset key
Error Code 65-1 or 65-2 appears in display
Follow 65-1 or 65-2

66

Game EPROM Changed

Turn power off - Turn power on

Store Location

Slot Depot
4642 S Highway 95
Fort Mohave, AZ 86426

Phone: 928 758-7282

E-mail: theslotdepot@npgcable.com

Store Hours

Fri 9:00am-4:30pm Sat 9:00am-3:00pm

Holiday Sale!

Stop in to check out all the items currently discounted for our holiday sale. Great deals, perfect for gifts.

Get Social with Us